The UVC 254nm ultraviolet light test equipment simulates the damage caused by the sun’s ultraviolet light and tests the weather resistance of the material under test by exposing it to light at controlled high temperatures. It uses ultraviolet lamps to simulate the effects of sunlight over a period of days or weeks.
UVC 254nm irradiation equipment can cause damage that would take months or even years to occur outdoors, These include fading, color change, tarnishing, powdering, cracking, wrinkling, foaming, embrittlement, reduction of oxidation and so on. Its test results can be used to select new materials, improve existing materials, or evaluate material formulation changes.
UVC 254nm test equipment comply with ISO 4892-1 (modified version) and EN 60335-1 Appendix T. The machine is
equipped with 8 pieces UVC254 ultraviolet fluorescent lamps with rated power of 36W. Continuous life of each UVC254 lamp
is more than 6000 hours. For good test performance purpose, Preferably, UVC 254nm machine can be installed in an air-
conditioned room. This will keep the room temperature between 21°C and 27°C, humidity lower than 85%RH and 86~106kpa
pressure.
It provides comprehensive and detailed real-time monitoring and curve recording for important test parameters such as irradiance, temperature and time (the controller has the function of paperless recorder). It can also generate reports and print curves through computer software.
Irradiation/room temperature test can be carried out alone, or any combination of two types of test can be programmed. Adopt
industrial level 7 inch true color touch screen control system, with good stability monitoring, operation and maintenance.
It provides life reference for ultraviolet lamps with expensive materials (UVC 254nm tubes are consumables with a life expectancy of more than 6000 hours), which is convenient for users to confirm replacement time of lamp and save use cost
The system has precise measurement and control of irradiance, Its control range: 8~13.0W/m2 adjustable. Can prolong the life
of the lamp tube, the test results are more accurate and reliable.
Through the irradiance measurement and control device, the irradiance can be measured and controlled, so that
the irradiance will automatically stabilize at the set value, and greatly prolong the service life of the UVC 254nm tube.
The installation and wiring of the electrical part of the equipment are carried out according to the international electrician
Standard. Our Tech team has perfect professional after-sales service.
Model |
QT-UV600-254 |
QT-UV800-254 |
Lamps Quantity |
PHILIPS, 8 Pieces |
|
Temperature Range |
RT+10°C~70°C |
|
External Dimensions (W x H x D) |
W:1300*H:1450mm*D:500mm |
W:1500*H:1500mm*D:550mm |
Light Temperature |
50°C~70°C |
|
Condensing Temperature |
40°C ~60°C |
|
Temperature Uniformity |
≤+-1.0°C |
|
Temperature Fluctuation |
≤+-0.5°C |
|
Standard Sample Size |
50*100mm |
|
Humidity |
Less than 95% |
|
Lamps Type |
PHILIPS TUV 36W |
|
Lamps Life |
6000 Hours |
|
Irradiation Intensity |
8~13.0W/m2 |
|
Wavelength Ultraviolet Light |
UVC 254 nm |
|
Power Supply |
AC 230V, 50Hz |
|
Gross Weight |
155 Kgs |
245 Kgs |