Rigid 4-column load frame construction providing superior axial and lateral stiffness and minimum maintenance, low reaction at specimen failure. Chrome plated columns for easy cleaning and longer life.
Extra-length screws and columns, with an adjustable lower crosshead, to increase the available test space for longer test specimens. Double acting crossbeam quickly accommodates specimens of varying lengths. In the case of the additional length of columns, the maximum testing space is adjustable to meet extra length specimens.
Fully open front hydraulic wedge grips make it easy to insert and remove specimens for increased productivity and operator safety. Interchangeable design allows a limited number of jaw faces to accommodate a large range of specimen sizes. Fully open front wedge clamps for easier loading and allowing rapid loading and unloading of specimens. Including grip control system mounted directly at the machine Tooling for tension, compression, bend/flex, shear, and other tests available. With digital displacement transducer for the best positioning and measuring accuracy.
The UTM is used to evaluate the tensile, compression, bend, and shear properties of materials including and metallic materials.
Qualitest’s High Strength Frame Dual Space Servo Hydraulic Universal Testing Machine series is used to verify various mechanical properties of:
Control Software is used to control the Universal testing machine. The Tester and the software are designed to accommodate a wide variety of testing needs. The software has a variety of pre-set programmed test cycles for compression, tensile and cyclical testing to meet a variety of testing standards.
A powerful Help wizard helps the operator to set up and connect the accessories in many phases. Includes installed packages of various test methods according to major national and international reference standards and different types of material to perform the following tests:
This program is complete with a graphic interface for
The structure of the software is very flexible giving the possibility to personalize the tests, process the results and certificates, and in particular, it is possible to
Metal |
|||||||||||||||||
Tensile tests at ambient temperature |
Compression tests at ambient temperature |
Shear Tests |
Strand tensile tests |
||||||||||||||
ASTM E8M–09 |
AS 1391 |
ISO 15630-2 |
ASTM C39 |
EN12390-3 |
ASTM E 143 |
ASTM A 416 |
|||||||||||
ASTM A370-07b |
ASTM A 706/A, |
706M - 6a |
ASTMC469 |
DIN1048 |
ASTM 496 |
||||||||||||
ASTM A185, A185M-07 |
ASTM A48M-03 |
EN 10002-1 |
ISO 4506 |
UNI6556 |
BS 5896 |
||||||||||||
ASTM A615, A615M-09 |
HB 5143 |
EN 10080 |
ISO6784 |
|
|
||||||||||||
ASTM A82, A82M – 07 |
ISO 15630-1 |
JIS Z 2241 |
|
||||||||||||||
Metals and Construction Material |
|||||||||||||||||
Bend Tests |
|||||||||||||||||
ASTM A185/A185M – 07 |
API 5L |
ISO 7438 |
|||||||||||||||
ASTM E190 |
AWS B4.0 |
|
|||||||||||||||
Welded Fabric |
|||||||||||||||||
Shear Tests |
|||||||||||||||||
ASTM E8M – 09 |
ASTM A82/ A82M |
ISO 15630-2 |
HB 5143 |
||||||||||||||
ASTM A370-07b |
ASTM A 706/A |
ISO 6394 |
JIS Z 2241 |
||||||||||||||
ASTM A185/ A185M |
AS 1391 706M - 06a |
BS 18 |
|
||||||||||||||
ASTM A615/A615M-09 |
ASTM A48M-03 |
EN 10002-1 |
|||||||||||||||
ASTM A82/ A82M – 07 |
ISO 15630-1 |
EN 10080– 07 |
|||||||||||||||
Fasteners |
|||||||||||||||||
Tensile tests for bolt |
Nut load keeping tests |
||||||||||||||||
ASTM F606-07 |
ISO 898-1 |
ASTM E290 – 09 |
ISO 7438 |
ISO 15630-2 |
JIS Z 2248 |
||||||||||||
AS 4291.1 |
|
ASTM A370-07b |
ISO 15630-1 |
ISO 10065 |
|
||||||||||||
Cement, Concrete and Rock |
|||||||||||||||||
Flexural tests for cement |
Compression tests for cement |
Flexural tests for concrete |
|||||||||||||||
ASTM C348 |
ASTM C349 -08 |
ASTM C 78 – 07 |
|||||||||||||||
ASTM C1609 /, C1609M |
ASTM C109, C109M – 08 |
ISO 1920-4 |
|||||||||||||||
ISO 679 |
ISO 679 |
|
|||||||||||||||
BS EN 196-1 |
BS EN 196-1 |
Model |
QT-HW2-600 |
QT-HW2-600-EXT |
---|---|---|
Capacity |
600kN |
|
Load Resolution |
Capacity/300, 000 (fully auto scaling of single measurement range) |
|
Stroke |
250 mm |
|
Testing Speeds |
0.1~70 mm/mi |
|
Adjustable Crosshead Speed |
350 mm/mi |
|
Diameter of Round Specimens for Tensile Test |
ᴓ6 ~ ᴓ 16 mm, ᴓ 13 ~ ᴓ 27 mm, ᴓ27 ~ ᴓ 40 mm |
|
Thickness of Flat Specimens for Tensile Test |
0 – 30 mm |
|
Width of Flat Specimens for Tensile Test |
<90mm |
|
Compression Platen Dimensions |
ᴓ 178mm |
|
Load Measurement Accuracy |
±0.5% of reading to 1/50 of load weighing system capacity meets or exceeds the requirements of the following standards: ISO 7500-1, EN 10002-2, ASTM E4, JIS B7721 |
|
Strain Measurement Accuracy |
±0.5% of reading to 1/50 of full scale with most ASTM E83 class B or ISO 9513 class 0.5 extensometers meets or exceeds ASTM E83, ISO 9513, and EN 10002-4. |
|
Speed Accuracy |
Set speed<10% Max. Speed: ±1% Set speed ≥10% Max. speed:±0.5% |
|
Position Measurement Accuracy |
±0.5 of reading or 0.001 mm, whichever is greater |
|
Power Supply |
3-Phase 380V/480V, 50/60 Hz, Power must be free of spikes and surges exceeding 10% of the nominal voltage.s |
|
Operating Temperature |
0 to +38°C (+32 to +100°F) |
|
Humidity Range |
10% to 90% non-condensing |
|
Storage Temperature |
-40 to +66°C (-40 to +150°F) |
|
Machine Dimensions |
||
Clearance Between Grips (H1) Piston Inside |
750 mm |
900 mm |
Clearance Between Platens (H2) Piston Inside |
750 mm |
900 mm |
Clearance Between columns (W) |
500mm |
500mm |
Dimensions WXDXH *Adjusted based on configuration |
950x600x2320 |
950x600x2500 |
Weight *Adjusted based on configuration |
2575kg |
2600kg |
Model |
QT-HW2-1000 |
QT-HW2-1000-EXT |
---|---|---|
Capacity |
1,000kN |
|
Load Resolution |
Capacity/300, 000 (fully auto scaling of single measurement range) |
|
Stroke |
250 mm |
|
Testing Speeds |
0.1~70 mm/mi |
|
Adjustable Crosshead Speed |
350 mm/mi |
|
Diameter of Round Specimens for Tensile Test |
ᴓ6 ~ ᴓ 20 mm, ᴓ 20 ~ ᴓ 40 mm, ᴓ 40 ~ ᴓ 60 mm |
|
Thickness of Flat Specimens for Tensile Test |
2 – 40 mm, 30 – 60 mm |
|
Width of Flat Specimens for Tensile Test |
<110mm |
|
Compression Platen Dimensions |
ᴓ 220mm |
|
Load Measurement Accuracy |
±0.5% of reading to 1/50 of load weighing system capacity meets or exceeds the requirements of the following standards: ISO 7500-1, EN 10002-2, ASTM E4, JIS B7721 |
|
Strain Measurement Accuracy |
±0.5% of reading to 1/50 of full scale with most ASTM E83 class B or ISO 9513 class 0.5 extensometers meets or exceeds ASTM E83, ISO 9513, and EN 10002-4. |
|
Speed Accuracy |
Set speed<10% Max. Speed: ±1% Set speed ≥10% Max. speed:±0.5% |
|
Position Measurement Accuracy |
±0.5 of reading or 0.001 mm, whichever is greater |
|
Power Supply |
3-Phase 380V/480V, 50/60 Hz, Power must be free of spikes and surges exceeding 10% of the nominal voltage.s |
|
Operating Temperature |
0 to +38°C (+32 to +100°F) |
|
Humidity Range |
10% to 90% non-condensing |
|
Storage Temperature |
-40 to +66°C (-40 to +150°F) |
|
Machine Dimensions |
||
Clearance Between Grips (H1) Piston Inside |
810 mm |
900mm |
Clearance Between Platens (H2) Piston Inside |
810 mm |
900mm |
Clearance Between columns (W) |
575mm |
575mm |
Dimensions WXDXH *Adjusted based on configuration |
1030x650x2500 mm |
1030x650x2600 mm |
Weight *Adjusted based on configuration |
3425 kg |
3450kg |
Model |
QT-HW2-2000 |
QT-HW2-2000-EXT |
---|---|---|
Capacity |
2,000kN |
|
Load Resolution |
Capacity/300, 000 (fully auto scaling of single measurement range) |
|
Stroke |
250 mm |
|
Testing Speeds |
0.1~70 mm/mi |
|
Adjustable Crosshead Speed |
330 mm/mi |
|
Diameter of Round Specimens for Tensile Test |
ᴓ5 ~ ᴓ 16 mm, ᴓ 15 ~ ᴓ 45 mm, ᴓ 40 ~ ᴓ 70 mm |
|
Thickness of Flat Specimens for Tensile Test |
0 – 40 mm, 30 – 70 mm |
|
Width of Flat Specimens for Tensile Test |
<150mm |
|
Compression Platen Dimensions |
330x330mm |
|
Load Measurement Accuracy |
±0.5% of reading to 1/50 of load weighing system capacity meets or exceeds the requirements of the following standards: ISO 7500-1, EN 10002-2, ASTM E4, JIS B7721 |
|
Strain Measurement Accuracy |
±0.5% of reading to 1/50 of full scale with most ASTM E83 class B or ISO 9513 class 0.5 extensometers meets or exceeds ASTM E83, ISO 9513, and EN 10002-4. |
|
Speed Accuracy |
Set speed<10% Max. Speed: ±1% Set speed ≥10% Max. speed:±0.5% |
|
Position Measurement Accuracy |
±0.5 of reading or 0.001 mm, whichever is greater |
|
Power Supply |
3-Phase 380V/480V, 50/60 Hz, Power must be free of spikes and surges exceeding 10% of the nominal voltage.s |
|
Operating Temperature |
0 to +38°C (+32 to +100°F) |
|
Humidity Range |
10% to 90% non-condensing |
|
Storage Temperature |
-40 to +66°C (-40 to +150°F) |
|
Machine Dimensions |
||
Clearance Between Grips (H1) Piston Inside |
760 mm |
890mm |
Clearance Between Platens (H2) Piston Inside |
760 mm |
890mm |
Clearance Between columns (W) |
575mm |
575mm |
Dimensions WXDXH *Adjusted based on configuration |
1300x900x2920 mm |
1300x900x3050 mm |
Weight *Adjusted based on configuration |
7825 kg |
7875kg |
Model |
QT-HW2-3000 |
---|---|
Capacity |
3,000kN |
Load Resolution |
Capacity/300, 000 (fully auto scaling of single measurement range) |
Stroke |
250 mm |
Testing Speeds |
0.1~70 mm/mi |
Adjustable Crosshead Speed |
260 mm/mi |
Diameter of Round Specimens for Tensile Test |
ᴓ20 ~ ᴓ 50 mm, ᴓ 50 ~ ᴓ 80 mm, ᴓ 80 ~ ᴓ 100 mm |
Thickness of Flat Specimens for Tensile Test |
0– 50 mm, 50 – 100 mm |
Width of Flat Specimens for Tensile Test |
<180mm |
Compression Platen Dimensions |
ᴓ 280mm |
Load Measurement Accuracy |
±0.5% of reading to 1/50 of load weighing system capacity meets or exceeds the requirements of the following standards: ISO 7500-1, EN 10002-2, ASTM E4, JIS B7721 |
Strain Measurement Accuracy |
±0.5% of reading to 1/50 of full scale with most ASTM E83 class B or ISO 9513 class 0.5 extensometers meets or exceeds ASTM E83, ISO 9513, and EN 10002-4. |
Speed Accuracy |
Set speed<10% Max. Speed: ±1% Set speed ≥10% Max. speed:±0.5% |
Position Measurement Accuracy |
±0.5 of reading or 0.001 mm, whichever is greater |
Power Supply |
3-Phase 380V/480V, 50/60 Hz, Power must be free of spikes and surges exceeding 10% of the nominal voltage.s |
Operating Temperature |
0 to +38°C (+32 to +100°F) |
Humidity Range |
10% to 90% non-condensing |
Storage Temperature |
-40 to +66°C (-40 to +150°F) |
Machine Dimensions |
|
Clearance Between Grips (H1) Piston Inside |
900 mm |
Clearance Between Platens (H2) Piston Inside |
900 mm |
Clearance Between columns (W) |
575mm |
Dimensions WXDXH *Adjusted based on configuration |
1390x990x4950 mm |
Weight *Adjusted based on configuration |
18000 kg |
1-877-884-8378